857 reviews analysed
1. HEATIT JHSF 6-feet 120V Self Regulating Pre-assembled Pipe Heating Cable
Feature
- JHSF doesn’t work unless the ambient temperature is below 37F/3 degree C. Please test the cable in a cold environment. HEATIT is registered Trademark by zhukeshi(We didn’t authorize other sellers in Amazon.com).
- Suitable for use on plastic and metal water pipes.( including inlet pipe,drain pipe, sewer , palm tree frost protection etc). Self regulating heating cable output will adjust automatically based on the ambient temperature at each point along the cable. No worry about the overheat risk. More Safe. Can be used by straight, spiral and overlap. More functional.
- Pre-assembled, easy to install. Including grounded plug with light, built in thermostat(turn the cable 37F on 50F off), and instructions. 120 volt, 3 watts/ft at 50 degrees F. Energy-efficient. Protect pipes up to 2″ in diameter. For a better freeze protection, at least 1/2 inch thick insulation material is recommended, especially for extremely cold weather.
- ETL approved. 2 ft 18/3 cold lead with plug. Industrial grade heat shrinkage tube for connection.The lowest installation temperature of this heating cable is -10 degree C. Tough XLPE as inner insulation and weather resistant PE (high-low temperature) as out jacket. Ingress Protection 65. Durable
- Testing the cable before the installation. Uncoil the cable, plug in the heating cable and then put the thermostat part of the cable into an ice bucket for few minutes. When the temperature is below 37F, the thermostat will energize the cable to work. Normally you can feel the slight warm on the heating cable in few minutes. Four year limited warranty. If you are not completely satisfied with HEATIT heating cable, please feel free to contact us in any time, we’ll try our best to solve your issue
2. Frost King HC30A Heating Cables, 30 Feet, Black
3. Thermwell Products HC18 Pipe Heat Cable 18 ft.
4. Easy Heat AHB-112 Cold Weather Valve and Pipe Heating Cable, 12-Feet
Feature
- Manufactured in china
- Easy to use
- Highly durable
- Easy Heat pipe heating cable installs quickly and easily to keep water flowing
- Includes grounded plug, built in thermostat, and instructions
- Each cable consists of tough PVC inner insulation, a continuous ground braid, and weather-resistant PVC outer jacket
- AHB units are activated and de-activated by an integral energy-saving thermostat
- Approved for rigid plastic and metal pipe
- UL listed
- Easy Heat pipe heating cable installs quickly and easily to keep water flowing
- Includes grounded plug, built in thermostat, and instructions
- Each cable consists of tough PVC inner insulation, a continuous ground braid, and weather-resistant PVC outer jacket
- AHB units are activated and de-activated by an integral energy-saving thermostat
- Approved for rigid plastic and metal pipe
- UL listed
Description
Easy Heat AHB-112 12′ Pipe Heating CableEasy Heat AHB-112 12′ Pipe Heating Cable Features: Tough PVC inner insulation Continuous ground braid Weather resistant PVC outer jacket Energy saving Thermostat is located between cold lead and heating cable 2′ 18/3 cold lead with grounded plug 84 watts 120 volts AC 12′ heated section
5. HEATIT JHSF1 Self Regulating ROOF & Gutter DE-Icing Pre-Assembled Heating Cable 100-feet 120V
Feature
- HEATIT is registered Trademark by zhukeshi(We didn’t authorize other sellers in Amazon.com). Suitable for use on plastic and metal water pipes( including inlet pipe,drain pipe, sewer, palm tree frost protection etc). Industrial grade self regulating heating cable. The cable output will adjust automatically based on the ambient temperature at each point along the cable. No worry about the overheat risk. More Safe. Can be used by straight, spiral and overlap. More functional.
- Protect pipes up to 2 1/2” in diameter. For a better freeze protection, at least 1/2 inch thick or thicker insulation material is recommended, especially for extremely cold weather. If the ambient temperature is lower than -20°F(-29°C), please use 1” thick insulation material.
- ETL approved. 50 degrees F for pipe freeze protection.3 ft 18/3 cold lead with grounded plug.
- Roof deicing application: Can be used on flat roofs, metal roofs, asphalt roofs, rubber roofs, slate roofs, stone roofs, metal roofs, ceramic roofs, composite (tar and gravel) roofs and so on. Rated 10W/ft at 32°F (0°C) for roof deicing. For roof deicing application, you may need to buy clips and hangers separately. For the circuit breaker requirement especially for the cables which length is over 100ft, please check the listed picture.
- Testing the cable before the installation. Uncoil the cable, plug in the heating cable. Normally you can feel the slight warm on the heating cable in few minutes. Two year limited warranty – If you are not completely satisfied with HEATIT heating cable, please feel free to contact us in any time, we’ll try our best to solve your issue.
6. Easy Heat AHB-019 Cold Weather Valve and Pipe Heating Cable, 9 feet
Description
Product Description
Easy Heat AHB-019 9′ Pipe Heating CableEasy Heat AHB-019 9′ Pipe Heating Cable Features: Tough PVC inner insulation Continuous ground braid Weather resistant PVC outer jacket Energy saving Thermostat is located between cold lead and heating cable 2′ 18/3 cold lead with grounded plug 63 watts 120 volts AC 9′ heated section
From the Manufacturer
Temperature-controlled cable runs straight along pipe and valves, held in place by application tape and plugs into grounded electrical outlet. Keeps water flowing down to -380. For odd lengths of pipe over 3/4 inches in diameter, we recommend two separate cables on opposite sides of the pipe with up to 3 feet of overrun at center of pipe run. Metal pipe requires 1/2-inch fiberglass insulation around cable. For plastic pipe, its recommended wrapping pipe with aluminum foil before cable installation. The traditional resistance cable produces a fixed amount of heat based on the electrical line feed. It comes with a built-in thermostat that switches the flow of electricity on and off based on temperature. 120 volts. 7 watts per foot. Not U.L. Listed.
7. TOPDURE JHSD 15-feet Pipe Heating Cable Built-in Thermostat
Feature
- Pre- assembled with power indicator light and built in thermostat (Below 37F ON, Over 50F OFF) .
- Prevent pipe freezing down to -40° F (-40° C).
- Used on water filled rigid metal and plastic pipes.
- 7watt/ft 120V.Can’t be cross, spiral or overlapped.
- 6ft 18/3 cold lead with grounded plug. 2 year warranty.
Description
11
8. TOPDURE TDSF Self Regulating Pre-assembled Pipe Heating Cable 30-feet 120V
Feature
- Heavy duty self regulating heating cable. Prevent pipes from freezing. Highly durable.
- Can be installed by spiral, crossing, straight etc. No overheat risk.
- Pre- assembled with power indicator light and built in thermostat (Below 37F ON, Over 50F OFF).
- 3W/ft @ 50F Lower temperature, higher wattage. ETL approved.
- 2ft 18/3 cold lead with grounded plug. 2 year warranty.
Description
11
9. HEATIT Mobile Home 100-feet HEATIT HTM Braid Self Regulating heating cable Water Line Freeze Protection
Feature
- HEATIT is registered Trademark by zhukeshi (We didn’t authorize other sellers in Amazon.com). HTM self-regulating pipe heating cable system is designed for mobile home and other dry applications etc. Can be used on residential metal or plastic water supply and drain pipe freezing protection.
- ETL approved. Tinned copper braid as the out jacket as well as electrical ground. Self regulating heating cable just deliver the heat where is need. The cable output will adjust automatically based on the ambient temperature at each point along the cable. No worry about overheat risk. More Safe. Can be used by straight, spiral and overlap. More functional.
- Additional tools which you may need: High quality electrician’s tape such as HEATIT glass cloth tape, 1/2” thick fiberglass insulation with vapor seal, wire cutters or heavy scissors, Phillips#2 slotted screw drivers, Ruler or measuring tape.
- HEATIT HTM connection kit is necessary for the pipe freeze protection application. Please purchase this kit separately.
- Quick test: Once insulation is finished, plug the cable into a 120V AC outlet. Don’t use any of the water for about 1 hour. After that turn on the tap on HEATIT HTM protected pipe and test the water temperature. You should feel the slight warm from the water.Three year limited warranty. If you are not completely satisfied with HEATIT heating cable, please feel free to contact us in any time, we’ll try our best to solve your issue
10. EasyHeat 2102 Freeze Free Heating Cable – 100′
Feature
- Self-regulating pipe heating system
- Provides flexible protection against pipe freeze-ups in even the most challenging applications
- Reduces power consumption when the pipe does not require freeze protection
- Ideal for use on residential metal or plastic water supply and drain pipes subject to freezing temperatures
- Length: 100′ and rugged metal braided jacket provides an electrical ground as well as protection against damage
Description
EasyHeat Freeze Free self-regulating pipe heating cables provide flexible protection against pipe freeze-ups in the most challenging applications. The cut-to-length technology is ideal for installations that require protection of numerous pipes of varied lengths. The self-regulating effect of the cable reduces power consumption when the pipe does not require freeze protection. They are ideal for use on residential metal or plastic water supply and drain pipes subject to freezing temperatures; water supply lines underneath manufactured homes; and cottages, barns and outbuildings that are not regularly used.
Conclusion